Detail Engineering for Solar PV & Battery Energy Storage
From rooftops to utility-scale solar parks—bankable, buildable, code-compliant design packages.
Bankable outputs
IFC drawings, BoM, specs, and studies accepted by lenders and authorities.
Integrated PV + BESS + Grid
End-to-end coordination—no siloed reports.
Lifetime-optimized
Design for maintainability to reduce OPEX & LCOE.
Solar PV Engineering
Complete electrical, structural, and documentation packages.
Electrical
- DC string sizing & layouts
- Cable routing & ampacity
- Protection & coordination
- Grid studies (SC, load flow, harmonics)
- SCADA / communications
Structural
- Fixed-tilt, ballast, trackers
- Wind/Snow to EN/ASCE
- Pile/footing sizing
- Roof integrity & ballast optimization
Documentation
- SLD, layouts, cable schedule
- Grounding & lightning plans
- Protection settings report
- IFC drawings, BoM & specs
Rooftop & Ground-Mounted
Rooftop (C&I)
- FEA of anchorage points
- Ballast optimization
- Fire safety & walkways
Ground-Mounted
- Topographical layouts
- Geotechnical-based pile design
- Drainage & access roads
Trackers
- Torque tube checks
- Backtracking
- Load cases
HSE
- Method statements / risk assessments
- Access & maintainability
Solar Parks (Utility-Scale)
Master Planning
- Land-use & setbacks
- 3D terrain / cut & fill
- Roads & drainage
MV/HV Design
- Up to 220 kV
- Substations AIS/GIS
- Protection schemes
Grid Compliance
- Reactive power
- Harmonics / flicker
- STATCOM / capacitor banks
Civil & Foundations
- Geotech → piles/rafts
- Seismic & wind
- Erosion control
SCADA
- Utility-grade
- Redundancy
- Cybersecurity
Bankability
- IEC/IEEE/ENTSO-E
- Environmental & social docs
- IE-ready packages
BESS (Battery Energy Storage)
Use-case & Sizing
- Peak shaving
- Arbitrage / firming
- Backup
Protection & EMS
- Coordination
- SCADA/RTU
- Metering
Thermal & Safety
- HVAC calculations
- NFPA 855 / UL 9540A
- E-stop & zoning
Layouts
- AC/DC schematics
- Grounding/bonding
- Containers & trays
Grid Integration & Compliance
Studies
- Load flow & short-circuit
- Harmonics & flicker
- Voltage rise
Protection
- Relay settings
- Breaker coordination
- Anti-islanding
Interconnection
- DSO/TSO documentation
- Grid codes (IEEE / ENTSO-E)
- Testing & commissioning
Permitting & Government Approvals
Building & Fire
- Structural & fire safety
- Egress & access
- Authority drawing packages
Environmental
- Noise & visual
- Mitigation in design
- Erosion & sediment control
Electrical & Grid
- IEC/NEC compliance
- Interconnection agreements
- OHS risk assessments
Software & Modeling
PVsyst
Energy yield & loss diagrams
ETAP / PowerFactory
Load flow, protection, harmonics
AutoCAD & Revit
M&E drawings & coordination
STAAD / SAP2000
Structural loads & trackers
ANSYS / SolidWorks
FEA: anchorage, ballast, fatigue
HOMER / MATLAB
Hybrid PV+BESS dispatch
O&M Engineering
Preventive
- PM schedules
- Checklists
- CMMS integration
Reliability
- MTBF/MTTR
- Spare parts
- RCA protocols
Repowering
- Module/inverter upgrades
- Life-extension
- Performance baselines
Q&A – Frequently Asked Questions
Do you also design storage?
Yes—PV, BESS, and full grid integration.
Are your designs bankable?
Compliant with IEC/IEEE/EN/NEC and accepted by lenders.
Do you work internationally?
Based in Denmark, serving Europe and beyond.
How do you ensure reliability?
Design for maintainability + O&M engineering.
What’s the first step?
Click the button below and share your project details.






